What the 9-12 high-pressure fan is
The 9-12 series high-pressure centrifugal fan is widely used for cupola furnace blast, carton machinery, and other duty that must overcome high system resistance. The "9-12" designation refers to a pressure coefficient of about 0.9 and a specific speed of about 12 — a low-specific-speed, high-pressure design with a narrower impeller of relatively large diameter, delivering high single-stage total pressure against long ducts, dense material beds, and similar resistance.
Pressure-first aerodynamics
A low-specific-speed backward impeller on a 2900 r/min two-pole motor delivers roughly 2000–4800 Pa of total pressure in a single stage.
Size 5A · 7.5kW build
Impeller diameter about 500 mm. The same size accepts a 5.5kW or 7.5kW motor; the 7.5kW build favors the higher-airflow section of the curve.
Direct-coupled drive
The impeller mounts straight on the motor shaft — no belt slip or tensioning maintenance, stable speed, compact layout, fewer service points.
Proven duty fit
Designed around cupola blast and carton-machine air duty, and also suited to high-pressure supply and pneumatic-conveying support.
9-12 series main technical parameters
Each size accepts motors of different power; the duty range shifts accordingly. The 5A + 7.5kW operating range is highlighted.
| Size | Power (kW) | Speed (r/min) | Airflow (m³/h) | Total pressure (Pa) |
|---|---|---|---|---|
| 5A | 5.5 | 2900 | 1000–2680 | 4800–3239 |
| 5A | 7.5 | 2900 | 2700–3400 | 3100–2065 |
| 6.3A | 7.5 | 2900 | 1000–1875 | 8000–8300 |
| 6.3A | 11 | 2930 | 1925–2750 | 8280–7850 |
| 6.3A | 15 | 2930 | 2800–4000 | 7830–6100 |
| 6.8A | 15 | 2930 | 1667–3600 | 9880–9420 |
| 6.8A | 18.5 | 2930 | 3667–4567 | 9350–8400 |
| 6.8A | 22 | 2930 | 4600–5500 | 8350–6760 |
| 7.1A | 15 | 2930 | 1201–2978 | 10515–10821 |
| 7.1A | 18.5 | 2930 | 3566–4148 | 10570–10103 |
| 7.1A | 30 | 2950 | 4818–6344 | 9490–6933 |
| 7.7A | 18.5 | 2930 | 1532–2983 | 12367–12953 |
| 7.7A | 37 | 2950 | 3798–6697 | 12727–10520 |
| 7.7A | 45 | 2970 | 7314–8092 | 9632–8154 |
Note: values are typical figures at standard conditions; the actual operating point moves along the fan performance curve as duct resistance changes. Selection should follow ZIFENG's tested performance curves and contract documents. Parameters for the same model may differ slightly across manufacturers.
Focus build: 5A + 7.5kWThis article
With a 7.5kW two-pole motor (2900 r/min), size 5A operates at 2700–3400 m³/h against 3100–2065 Pa. Compared with the 5.5kW build of the same size (1000–2680 m³/h at 4800–3239 Pa), the 7.5kW curve shifts to the right — more airflow at the same pressure — fitting systems with moderate resistance and a steady demand for higher volume.
The two curves meet near 2700 m³/h / 3100 Pa. If system resistance is high and required airflow stays below roughly 2680 m³/h, the 5.5kW build runs more economically; if the demand exceeds 2700 m³/h at relatively lower resistance, the 7.5kW build fits better. Check both against your measured system resistance curve.
Strengths and limits
Every model has its boundaries — here is the engineering view of the 9-12 5A.
ProsStrengths
- High single-stage total pressure (up to about 4800 Pa at size 5A) without two-stage series connection
- Backward impeller offers higher efficiency and lower energy use over long running hours
- Non-overloading characteristic — the motor is less likely to overload when system resistance changes
- Direct-coupled drive: no belt slip or tensioning, stable speed, fewer maintenance points
- Compact footprint with anti-vibration base mounts for straightforward installation
- Well-proven in cupola and carton-machinery duty, with long industry field record
Limits & cautionsBoundaries
- Noise is relatively noticeable at 2900 r/min two-pole speed; silencers and acoustic measures are needed in noise-sensitive spots
- Strict medium requirements: non-corrosive, non-flammable, non-viscous gas, temperature up to 80℃, dust and hard particles below 150 mg/m³
- Airflow range centers on 2700–3400 m³/h; larger volumes should move up to size 6.3A and above
- Fixed direct-drive speed; capacity control needs a VFD (check inverter compatibility at two-pole speed)
- High-pressure duty demands tight impeller balancing and casing sealing — quality varies widely at low price points, so choose a dependable supplier
Where it fits
The pattern to look for: moderate airflow + high pressure + clean, ambient-temperature gas.
Cupola / melting furnace blast
Combustion air that must overcome the burden-bed resistance — the traditional core duty of the 9-12 series.
Carton machinery air duty
High-pressure air for suction, conveying, and dust extraction on carton production lines, with stable flow-pressure matching.
High-pressure supply / boosting
Boosting supply air through long ducts or high-resistance filters, or supplementing systems that fall short on pressure.
Pneumatic-conveying support
Support air for conveying light, clean, dry particles such as wood shavings — provided the medium limits are met.
Three duty types should look elsewhere: dusty or sticky media (choose an abrasion/dust-handling fan); medium above 80℃ (choose a high-temperature furnace fan); high airflow at low pressure (a medium-pressure series such as 4-72 runs more economically).
Five checks for the 5A 7.5kW build
Work through in order; if any step fails, consider an adjacent size or another series.
Verify the medium
Non-corrosive, non-flammable, non-viscous, temperature ≤80℃, dust ≤150 mg/m³ — all must hold before selecting this series.
Calculate system resistance
Total duct + equipment + bed resistance should fall near 2000–3100 Pa for the 5A 7.5kW to run near its efficient zone; above about 3200 Pa, look at the 5.5kW build or size 6.3A.
Match the airflow demand
Required volume between 2700–3400 m³/h fits directly; below 2680 m³/h consider the 5.5kW build, above 3400 m³/h move to 6.3A.
Allow margin
Keep roughly 10% margin on airflow and pressure, but avoid oversizing — high-pressure fans lose efficiency noticeably when running far from the design point.
Confirm installation and auxiliaries
Check foundation loading, vibration isolation, 380V supply, starting method (reduced-voltage or soft start recommended), and noise measures, then sign off the technical agreement.
Hand these four to an engineer — airflow, total pressure, medium temperature and dust content, and installation conditions; it beats judging by model name alone.
Why source your high-pressure fan from ZIFENG
From duty-point calculation to complete delivery, with full-process support.
ZIFENG FANS supplies the full 9-12 series from size 5A to 7.7A, covering motor builds from 5.5–45kW, with material, drive, and control options customized to your medium and installation. Every unit is dynamically balanced and performance-tested before shipment, with the test report delivered alongside the fan.
- Full 9-12 size range in supply, with 5A / 5.5kW and 5A / 7.5kW builds readily available
- Duty points checked against measured system resistance to avoid oversizing waste
- Impeller balancing + complete-unit performance testing, traceable quality
- Optional VFD cabinets, silencers, and anti-vibration bases as one-stop auxiliaries
Selection is a service
5.5–45kWMotor builds across the full 9-12 range from size 5A to 7.7A, matched to your duty.
Test reportEvery unit ships with balancing and performance records, so rated values hold up on site.
Need a 9-12 5A 7.5kW high-pressure fan proposal?
Send us your airflow, total pressure, medium, and installation conditions — our engineering team will verify the duty point and recommend the configuration.