News

Home / News / Industry News / YN5-47 Boiler Induced Draft Fan

YN5-47 Boiler Induced Draft Fan

YN5-47 Boiler Induced Draft Fan: Complete Guide for Boiler Manufacturers & Distributors

If you build or service small industrial boilers, heating furnaces, hot-air stoves or drying systems, the YN5-47 boiler induced draft fan is one of the most widely matched ID-fan series on the Chinese market. This guide covers what it is, how its air-cooled high-temperature design works, the full 12-model specification table, and how to source it factory-direct from ZIFENG.

What Is the YN5-47 Boiler Induced Draft Fan?

The YN5-47 is a high-efficiency, low-noise, air-cooled, high-temperature resistant centrifugal fan purpose-built for induced draft (ID) duty on small boilers and combustion equipment. Installed on the flue-gas side of the system, it extracts hot gas from the combustion chamber and maintains the slight negative pressure that keeps fuel burning steadily and completely.

Unlike general-purpose centrifugal fans, the YN5-47 is engineered specifically for the two defining conditions of boiler ID service: continuous high-temperature gas and long operating hours. That is why it has become a standard supporting component for heating boilers, hot-air furnaces, numerical-control boilers, steam boilers, and drying, chemical, food and grain-processing machinery.

5 Design Features That Make the YN5-47 Suitable for Boiler Duty

1. Air-cooled, high-temperature resistant structure

An insulated connection seat separates the hot flue-gas passage from the drive end, and a dedicated cooling impeller continuously dissipates heat around the bearing and motor zone. The fan handles hot flue gas without any water-cooling hookup — simpler piping, lower installation cost, and no risk of cooling-water failure.

2. Y2 aluminum die-cast motor

The series uses Y2-series aluminum-housing motors: light, quick to dissipate heat, and dimensionally consistent — which keeps the whole unit compact enough to fit tight boiler casings.

3. Integrated laser-cut air inlet

The inlet is cut in one piece by CNC laser, so the flow passage stays smooth and concentric. The result is higher static efficiency, lower noise, and stable performance curves between units — important when you are matching fans to boiler models in volume.

4. Laser-cut scroll casing

Scroll housings are laser-cut for clean seams and an even weld finish — a small detail that matters when the fan is visible inside your boiler cabinet or exported under your own brand.

5. Flexible configuration

Mounting feet, inlet flanges, discharge flanges, material upgrades (e.g. stainless steel for corrosive gas) and rotation/angle combinations can all be configured to your boiler layout. Both left-hand (LG) and right-hand (RG) rotation are available, each with 8 discharge angles.

YN5-47 Technical Parameters: Full 12-Model Table

The series spans 12 power ratings from 60W to 3kW, with airflow of 240–3,800 m³/h and total pressure of 310–1,580 Pa. All models run on 2-pole motors at 2,800 r/min with 220/380V, 50Hz supply.

Model Power (W) Voltage (V) Frequency (Hz) Speed (r/min) Air volume (m³/h) Total pressure (Pa)
YN5-47 60 220/380 50 2800 240 310
YN5-47 90 220/380 50 2800 350 360
YN5-47 120 220/380 50 2800 480 450
YN5-47 180 220/380 50 2800 650 510
YN5-47 250 220/380 50 2800 860 580
YN5-47 370 220/380 50 2800 1100 650
YN5-47 550 220/380 50 2800 1450 680
YN5-47 750 220/380 50 2800 1810 790
YN5-47 1100 220/380 50 2800 2250 940
YN5-47 1500 220/380 50 2800 2800 1140
YN5-47 2200 220/380 50 2800 3100 1280
YN5-47 3000 220/380 50 2800 3800 1580

Data source: official ZIFENG product catalog. Outline and installation dimension drawings for each size are available on request.

How to Select the Right YN5-47 Model

Three inputs decide the model: required flue-gas volume (m³/h), system resistance converted to required total pressure (Pa), and gas temperature. A practical workflow:

  • Match airflow to combustion output. Take the flue-gas volume from your boiler design data (or fuel consumption × excess-air ratio), then pick the size whose air volume covers it at your operating point.
  • Keep a pressure margin. Choose a model whose total pressure exceeds your calculated system resistance (ducts, dampers, dust collector) — typically with a 10–15% allowance, without oversizing so far that the fan runs far off its best-efficiency point.
  • Confirm temperature duty. For continuously hot flue gas, the air-cooled structure is the standard choice; tell us your gas temperature so we confirm suitability and any material options.
  • Send us the duty point. If you are unsure, simply send gas volume, pressure, temperature and boiler type — our engineers will recommend the size and return an outline drawing for your layout.

Rotation and Discharge Angles for Easy Boiler Integration

The YN5-47 is offered in left-hand (LG) and right-hand (RG) rotation, each with 8 discharge outlet angles. This lets you route the flue-gas duct upward, sideways or horizontally without redesigning your boiler casing — and it is also why many boiler OEMs standardize on this series across their model lineups.

Typical Applications

  • Small industrial steam boilers and hot-water boilers (induced draft)
  • Heating furnaces, hot-air stoves and heat-treatment equipment
  • Biomass and coal-fired combustion systems
  • Drying machinery in food, chemical, grain and agricultural processing

Why Source YN5-47 Fans from ZIFENG?

Zhejiang Zifeng Fan Co., Ltd. (ZIFENG) is located in Daxi Town, Wenling City, Zhejiang Province — one of China's densest clusters of fan and machinery manufacturing. We focus exclusively on the R&D and production of industrial ventilation equipment.

  • Manufacturer, not a middleman:20,000 m² plant with laser cutting, CNC spinning, hydraulic presses and vertical lathes in-house — blanking to dynamic balancing under one roof.
  • 100+ finalized models: one supplier for ID fans, 4-72 low-pressure fans, 9-19/9-26 high-pressure fans and stainless-steel corrosion-resistant series.
  • Certified quality system: ISO9001:2015 certified; CE certification for EU-bound products.
  • OEM/ODM ready: custom voltage/frequency, discharge angles, materials and private labeling for boiler OEMs and distributors.
  • Direct factory pricing with export packing and documentation support.

Frequently Asked Questions

What is the YN5-47 boiler induced draft fan used for?

It is a centrifugal ID fan for small industrial boilers, heating furnaces, hot-air stoves and drying equipment. It draws flue gas out of the combustion chamber and maintains negative pressure for stable, efficient combustion.

What power ratings does the YN5-47 series cover?

12 power ratings from 60W to 3kW, with air volume of 240–3,800 m³/h and total pressure of 310–1,580 Pa, on 2-pole motors at 2,800 r/min (220/380V, 50Hz).

How does the YN5-47 withstand high flue-gas temperatures?

Its air-cooled, high-temperature resistant structure uses an insulated connection seat plus a dedicated cooling impeller, so it handles hot flue gas without a water-cooling system.

Can the YN5-47 be customized for 60Hz or different voltages?

Standard supply is 220/380V, 50Hz. Voltage and frequency options for export markets (e.g. 60Hz) can be arranged — send your requirement for confirmation.

Are you a factory or trading company? Do you support OEM?

ZIFENG is a manufacturer with a 9,600 m² plant, 100+ finalized models, ISO9001:2015 certification and CE certification for the EU market. OEM/ODM and private labeling are supported.

Get a Free Quotation for YN5-47 Boiler Fans

Tell us your gas volume, pressure, temperature and boiler type — our engineers will recommend the right YN5-47 size within one working day, with outline drawings and factory-direct pricing.